Báo cháy GST

  • Đầu báo nhiệt (12V)

    Xem và tải Catalogue
    - Đầu báo 4 dây, điện áp làm việc 12V.
    - Ngõ ra NO 1A/30VDC
    - Điện áp làm việc: 9.6VDC-14.4VDC
    - Dòng diện làm việc: 
    Dòng tỉnh 
    Dòng báo động >20mA
    - Reset sau khi báo động: max 5s, max 2.5VDC
    - Power-up time < = 10s.
    - Nhiệt độ làm việc: -10°C+50°C@95%
    Liên hệ
    Mua nhanh
  • Đầu báo gas

    Xem và tải về Catalogue

    Description: 
    C-9602LW Conventional Gas Detector is 
    wall-mounted, designed to check and monitor 
    the gas of leakage in such applications as 
    houses, hotels and apartments. 
    Specification 
    1. Operating Voltage:187VAC~253VAC 
    2. Power Consumption: 
    Standby State≤3.0 W 
    Alarm State≤5.0 W 
    3. Output capacity and control mode: 
    Voltage contact: For 12VDC one-way pulse 
    solenoid, whose driving capability is 1000µF 
    capacitance discharge. 
    Volt-free contact: Volt-free normally open 
    contact, its capacity is 220V/1A used for 
    controlling connected devices. 
    4. Alarm Density: 
    Natural Gas: 3000×10-6
    (6%LEL) 
    Liquefied Petroleum Gas: 2000×10-6
    (10%LEL) 
    Coal Gas: 400×10-6
    (1%LEL) 
    5. Indicator: 
    Power LED: Green, flashes in warm-up state 
    and then constantly lights. 
    Alarm/Fault LED: Dual color. It’s red when 
    alarming, and yellow in fault. 
    6. Buzzer: It sounds twice every second when 
    alarming, and once every three seconds in 
    fault. 
    7. Self Test: Pressing Self-Test, the LEDs will 
    flash in turn and the buzzer will sound three 
    times. 
    8. Life of Sensor: 5 years 
    9. Operating Environment: 
    Temperature: -10℃~ +50℃ 
    Relative Humidity≤95%, non condensing 
    10. Dimension: 121mm×87mm×47mm 
    11. Ingress Protection Rating: IP30 
    12. Material and Color of Enclosure: 
    ABS, ivory white 
    13. Weight: 320g 
    14. Mounting Hole Distance: 15mm
    Liên hệ
    Mua nhanh
  • Trung tâm báo cháy 8 zone

    Xem và tải về Catalogue

    1.1 Features: —

    - 2 to 16 zones can be detected, compatible with conventional detectors and manual call points. Each of the 16 detection zones can be individually configured as maximum 15 conventional detectors. The total number of detectors and manual call points in a zone shall not exceed 32.

    - 4 sounder outputs, 1 alarm output and 1 fault output.

    - Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output.

    - Designed with standby batteries and space provision for two sealed lead-acid batteries.

    - Test and disable functions. — Day/night mode settable.

    - Programmable on manual call point connection, sound modes, sounder delay modes and output delay modes.

    - Three access levels settable via a key switch and an internal switch. 

    - Reserved repeater panel interface for fire alarm indication of multiple zones.

    - Providing external ports includes RESET, SILENCE, EVAC and forced Night Mode.

    1.2 Technical Specifications:

    1.2.1 Operating Voltage: — Input Voltage: 220V/230VAC+10% -15% — Frequency: 50/60Hz — Input Current: 0.35 A — Fuse: 2A delayed — Recommended Wiring: 1.5mm2 or above shield cable, complying with local installation codes.

    1.2.2 Batteries:  Minimum Operating Voltage: 21.5V 

    - Maximum Charging Current: 315mA —

    - Maximum Charging Voltage: 27.6V — Battery Type: Sealed lead-acid battery —

    - Maximum Battery Charging Capacity: 2 batteries, 7Ah/12V. — Recommended Battery Manufacturer and Model: Yuasa NP7-12 — Maximum internal resistance of the batteries: 1Ω —

    - Standby current of batteries when fully load: 0.1A — Maximum operating current of the batteries: 2.5A

    -— Recommended Wiring (subject to local installation codes): GST fire cable Vencroft Gold and Platignum Nexans NX 200 and 200 Plus (LPCB tested) Prysmian FP 200 and 200 Gold Draka Firetuf and Firetuf Plus And all LPCB approved fire cables.

    Liên hệ
    Mua nhanh
  • Trung tâm báo cháy 16 zone

    Xem và tải về Catalogue

    1.1 Features:


    —- 2 to 16 zones can be detected, compatible with conventional detectors and manual call points. Each of the 16 detection zones can be individually configured as maximum 15 conventional detectors. The total number of detectors and manual call points in a zone shall not exceed 32. 
    —- 4 sounder outputs, 1 alarm output and 1 fault output. 
    —- Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output. 
    —- Designed with standby batteries and space provision for two sealed lead-acid batteries. 
    —- Test and disable functions. 
    —- Day/night mode settable. 
    —- Programmable on manual call point connection, sound modes, sounder delay modes and output delay modes. 
    —- Three access levels settable via a key switch and an internal switch. 
    —- Reserved repeater panel interface for fire alarm indication of multiple zones. 
    —- Providing external ports includes RESET, SILENCE, EVAC and forced Night Mode.

    1.2 Technical Specifications:
    - 1.2.1 Operating Voltage:
    — Input Voltage: 220V/230VAC+10% -15%
    — Frequency: 50/60Hz 
    — Input Current: 0.35 A 
    — Fuse: 2A delayed 
    — Recommended Wiring: 1.5mm2 or above shield cable, complying with local installation codes.
    - 1.2.2 Batteries:
    — Minimum Operating Voltage: 21.5V 
    — Maximum Charging Current: 315mA
    — Maximum Charging Voltage: 27.6V 
    — Battery Type: Sealed lead-acid battery 
    — Maximum Battery Charging Capacity: 2 batteries, 7Ah/12V. 
    — Recommended Battery Manufacturer and Model: Yuasa NP7-12 
    — Maximum internal resistance of the batteries: 1Ω 
    — Standby current of batteries when fully load: 0.1A 
    — Maximum operating current of the batteries: 2.5A 
    — Recommended Wiring (subject to local installation codes): 
    GST fire cable 
    Vencroft Gold and Platignum 
    Nexans NX 200 and 200 Plus (LPCB tested) 
    Prysmian FP 200 and 200 Gold 
    Draka Firetuf and Firetuf Plus And all LPCB approved fire cables
    Liên hệ
    Mua nhanh
  • Trung tâm báo cháy 4 zone

    Xem và tải về Catalogue

    1.1 Features:

    - —2 to 16 zones can be detected, compatible with conventional detectors and manual call points. Each of the 16 detection zones can be individually configured as maximum 15 conventional detectors. The total number of detectors and manual call points in a zone shall not exceed 32. 

    - 4 sounder outputs, 1 alarm output and 1 fault output.

    -— Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output.

    -— Designed with standby batteries and space provision for two sealed lead-acid batteries.

    -— Test and disable functions. — Day/night mode settable.

    - Programmable on manual call point connection, sound modes, sounder delay modes and output delay modes.

    - Three access levels settable via a key switch and an internal switch.Reserved repeater panel interface for fire alarm indication of multiple zones. —

    - Providing external ports includes RESET, SILENCE, EVAC and forced Night Mode.

    1.2 Technical Specifications:

    - 1.2.1 Operating Voltage: — Input Voltage: 220V/230VAC+10% -15% — Frequency: 50/60Hz — Input Current: 0.35 A — Fuse: 2A delayed — Recommended Wiring: 1.5mm2 or above shield cable, complying with local installation codes.

    - 1.2.2 Batteries: — Minimum Operating Voltage: 21.5V — Maximum Charging Current: 315mA — Maximum Charging Voltage: 27.6V — Battery Type: Sealed lead-acid battery — Maximum Battery Charging Capacity: 2 batteries, 7Ah/12V.

    - Recommended Battery Manufacturer and Model: Yuasa NP7-12 — Maximum internal resistance of the batteries: 1Ω — Standby current of batteries when fully load: 0.1A — Maximum operating current of the batteries: 2.5A 

    - Recommended Wiring (subject to local installation codes): GST fire cable Vencroft Gold and Platignum Nexans NX 200 and 200 Plus (LPCB tested) Prysmian FP 200 and 200 Gold Draka Firetuf and Firetuf Plus And all LPCB approved fire cables

    Liên hệ
    Mua nhanh
  • Trung tâm báo cháy 2 zone

    Xem và tải về Catalogue

    1.1 Features:

    - —2 to 16 zones can be detected, compatible with conventional detectors and manual call points. Each of the 16 detection zones can be individually configured as maximum 15 conventional detectors. The total number of detectors and manual call points in a zone shall not exceed 32.

    - 4 sounder outputs, 1 alarm output and 1 fault output.

    - — Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output.

    - Designed with standby batteries and space provision for two sealed lead-acid batteries.

    - Test and disable functions. — Day/night mode settable.

    -— Programmable on manual call point connection, sound modes, sounder delay modes and output delay modes.

    - Three access levels settable via a key switch and an internal switch.

    -— Reserved repeater panel interface for fire alarm indication of multiple zones.

    - Providing external ports includes RESET, SILENCE, EVAC and forced Night Mode.

    1.2 Technical Specifications:

    - 1.2.1 Operating Voltage: — Input Voltage: 220V/230VAC+10% -15%

    -— Frequency: 50/60Hz — Input Current: 0.35 A

    -— Fuse: 2A delayed

    -— Recommended Wiring: 1.5mm2 or above shield cable, complying with local installation codes.

    - 1.2.2 Batteries: — Minimum Operating Voltage: 21.5V 

    - Maximum Charging Current: 315mA — Maximum Charging Voltage: 27.6V

    -— Battery Type: Sealed lead-acid battery.

    -— Maximum Battery Charging Capacity: 2 batteries, 7Ah/12V.

    -— Recommended Battery Manufacturer and Model: Yuasa NP7-12.

    -— Maximum internal resistance of the batteries: 1Ω 

    - Standby current of batteries when fully load: 0.1A

    -— Maximum operating current of the batteries: 2.5A

    -— Recommended Wiring (subject to local installation codes): GST fire cable Vencroft Gold and Platignum Nexans NX 200 and 200 Plus (LPCB tested) Prysmian FP 200 and 200 Gold Draka Firetuf and Firetuf Plus And all LPCB approved fire cables.

    Liên hệ
    Mua nhanh
  • Bộ hiển thị phụ

    Xem và tải về Catalogue

    Mô tả:

    ·          Dùng cho tủ GST-102-104-108-116

    ·          Điện áp lấy trực tiếp từ tủ trung tâm

    ·          Bộ hiện thị phụ GST-RP-16, sử dụng cho hệ thống báo cháy dạng vùng, dùng để hiển thị thông tin hệ thống báo cháy, được sử dụng trong các tòa nhà, trung tâm điều khiển báo cháy. Khi tủ trung tâm báo cháy nhân tín hiệu cháy, nó sẽ báo động và gởi tín hiệu đỏ đèn bộ hiển thị GST-RP-16, bộ hiện thị sẽ hiển thị vùng cháy và phát âm thanh cảnh báo.

     Đặc điểm kỹ thuật:

    ·          Điện áp vận hành: 18VDC-28VDC.

    ·          Dòng vận hành tĩnh: 12mA, khi có báo động: 60mA

    ·          Nhiệt độ làm việc: 00C -0C

    ·          Hiển thị 16 vùng cảnh báo. 2 tín hiệu báo lỗi.

    ·          Sử dụng trong nhà.

    ·          Kích thước: 280mm x 110mm x 46mm

    Liên hệ
    Mua nhanh
  • Tủ báo cháy GST101

    3.100.000 đ
    Mua nhanh
  • Tủ báo cháy GST102

    3.350.000 đ
    Mua nhanh
  • Active end of line

    Dùng cho hệ báo cháy thường.
    Nó có thể dùng dạng như một đế đầu báo thong thường, hoặc dùng độc lập với nắp che.
    Chỉ thị đầu báo bị tháo.
    Tương thích với tất cả các tủ báo cháy hệ thường của GST
    Tương thích với modun giao tiếp giữa hệ thường và hệ địa chỉ I-9319
    Tương thích với đầu báo C-9101/2/3/4
    Liên hệ
    Mua nhanh